primary coil
Also written Primary Coil, Primary coil
As the sources put it
Primary coil (26) is electrically isolated (no electrical connection between primary 26 and secondary coil) to form Voltage Intensifier Circuit (60) of Figure (3-22).
Where it appears · 59
Documents 16
-
Transformer Action
9× · introduced
…(7-8) cross over to Secondary Pickup Coil-winding (52) which has more turns of wire than Primary Coil- winding (26) by way of "Eddy" currents that induce magnetic flux lines of forces (71a xxx 71n) emanating awa…
-
Voltage Intensifier Circuit (60)
4× · introduced
…Figure (3-15) with variable controlled switch-gate (49a xxx 49n) of Figure (3-18) across primary coil (26) of Figure (3-22), Figure (3-15) Figure (3-18) variable amplitude pulse-train (51a xxx 51n) of Figure (3-…
-
Tri - Coil Construction
2× · introduced
…xxx 501n) electrically connected in sequential order to form resistive pickup coil (503). Primary Coil (26) (typically .030 Ga.) film coated magnet wire is longitudinal wrapped in space relationship on top of and…
-
Voltage Amplitude Control Circuit (50)
2× · introduced
…regulates car battery electrical voltage potential (32) of Figure (3-15) being applied to primary coil (26) of Figure (3-21); and secondly, regulates gas pressure of Fuel Cell (120) of Figure (3-22), as graphical…
-
Cell Driver Circuit (90)
2× · introduced
…nction by switching "off' and "on" electric ground being applied to opposite side (48) of primary coil (26) of Figure (3-19). Figure (3-18) Figure (3-19) The resultant pulse wave form (49a xxx 49n) of Figure (3-1…
-
VIC Switchover Circuit
2× · introduced
…tensity on both stationary voltage fields (952/953) are similar due to the fact that both primary coil (957) and secondary coil (958) comprising and forming voltage intensifier circuit (990) of Figure (10-3) are…
-
Electron Bounce Phenomenon
1× · introduced
…oil (26) and Secondary coil (52) with fields aiding. Coupling Inductance (Rp) between the Primary coil (26) and Secondary Coil (52) is further extrapolated in the following equation: Where, (Lt) is the total indu…
-
Analog Voltage generator (40)
1× · introduced
…voltage amplitude control circuit (50) of Figure (3-5) which is is electrically linked to primary coil (26) of Figure (3-22) of Voltage Intensifier Circuit (60) of Figure (3-5). Figure (3-22) Figure (3-5)…
-
Propagating Electrical Stress
1× · introduced
…Inductance Fields" (Rp1/Rp2) once secondary coil (62) is electromagnetically energized by primary coil (56) and vice versa ... thereby, preventing amp "in-fluxing" (discouraging electron arc over) across Dielectr…
-
Capacitance (Cd)
1× · introduced
…15) 430F/FR 36 AWG (.006) stainless steel (s/s) wire equals 60 micro ohms per centimeter; Primary Coil (622) 22 AWG (.028) copper wire equals 5.1933 ohms per pound weight; Secondary Pickup Coil (623) 35 AWG (.007…
-
Voltage Amplitude Switch-Off
1× · introduced
…e member of Secondary Coil-Array (505a xxx 505n) maximizes electrical power transfer from Primary Coil (26) to Secondary Coil (52) by keeping Voltage Amplitude of Pulse-train (49a xx 49n - T3 - 49a xxx 49n) const…
-
ENERGY of the FUTURE - R&Z - Vol 2 No. 3, 1991
4×
…ugh voltage amplitude control circuit (50) of Figure (4) which is electri cally linked to primary coil (26) of Figure (20) of Voltage Intensifier Cir- cuit (60) of Figure (4). Voltage Amplitude Control Circuit (5…
-
ENERGY of the FUTURE - R&Z - Vol 1 No. 6, 1990
1×
…rmer (a/g) steps up voltage amplitude or voltage potential during pulsing operations. The primary coil is electrically isolated (no electrical connection between primary and secondary coil) to form Voltage Intens…
-
Pulsing Transformer
1×
…(A/G) steps up the voltage amplitude or voltage potential during pulsing operations. The primary coil is electrically isolated (no electrical connection between primary and secondary coil) to form Voltage Intens…
-
RE: Electrical Particle Generator
1×
…te, and use magnetized gas to produce electrical energy on demand. Operational Parameters Primary Coil (L) Variable Pulse Voltage Frequency (h) D-110 VDC Isolated Pulsing Transformer (m) Blocking Diode (f) Resona…
-
CIRCUIT COMPONENT INTERACTION
1×
…former (m) steps up voltage amplitude or voltage potential during pulsing operations. The primary coil is electrically isolated (no electrical connection between primary and secondary coil) to form Voltage Intens…
Patents 6
-
A control and driver circuits for a hydrogen gas fuel producing cell
15×
…lizing the dielectric properties of water as part of the electronic resonant circuit. The primary coil of the isolation transformer is connected to a pulse generation means. The secondary coil of the transformer…
-
Process & Apparatus For The Production Of Fuel Gas & The Enhanced Release Of Thermal Energy From Such Gas
4×
…d, Ohio) No. F626-1205. The core is 1.50 inch in 6 diameter and 0.25 inch in thickness. A primary coil of 200 turns of 24 gauge cooper wire is provided and a coil of 600 turns of 36 gauge wire comprises the secon…
-
Process And Apparatus For The Production Of Fuel Gas And The Enhanced Release Of Thermal Energy From Such Gas
4×
…land, Ohio) No. F626-1205. The core is 1.50 inch in diameter and .25 inch in thickness. A primary coil of 200 turns of 29 gauge copper wire is provided and a coil of 600 turns of 36 gauge wire comprises the secon…
-
Method For The Production Of A Fuel Gas
3×
…and, Ohio) No. F626-1205. The core is 1.50 inch in diameter and 0.25 inch in thickness. A primary coil of 200 turns of 24 gauge copper wire is provided and a coil of 600 turns of 36 gauge wire comprises the secon…
-
Method For The Production Of A Fuel Gas
3×
…and, Ohio) No. F626-1205. The core is 1.50 inch in diameter and 0.25 inch in thickness. A primary coil of 200 turns of 24 gauge copper wire is provided and a coil of 600 turns of 36 gauge wire comprises the secon…
-
Electrical Particle Generator
1×
…ization will sustain some motion. As the particles approach the accelerator assembly, the primary coil, the field therein attracts the particles and accelerate the particles to enter the gap in the coil. As the m…
Bench findings 37
-
Secondary coil has more turns than primary coil in VIC transformer
2×
The Secondary Pickup Coil-winding (52) has more turns of wire than the Primary Coil-winding (26), producing step-up transformer action via magnetic flux lines induced by pulsing of the Primary Coil.…
-
Figure 9 circuit enhances voltage across resonant charging choke coils via external pulsing field
1×
…ls during pulsing by allowing an external electromagnetic pulsing field F, from energized primary coil A, to traverse coil windings D and E (energized by incoming pulse train Ha...Hn through switching diode G); t…
-
VIC Primary Coil uses 22 AWG copper wire at 5.1933 ohms/lb
1×
The Primary Coil (622) of the VIC uses 22 AWG (.028 in) copper wire equal to 5.1933 ohms per pound weight.…
-
VIC Core is grain-oriented electrical steel laminated inductance core
1×
…minations that step up applied voltage when magnetic field coupling crosses over from the Primary Coil-winding (26) to the Secondary Pickup Coil-winding (52).…
-
VIC transformer impedance ratio relates primary/secondary magnetic field strengths
1×
…he VIC transformer is determined from the sum of the magnetic field strength (FL4) of the primary coil (26) and the induced magnetic field (FL3) of the secondary pickup coil (52) during each pulse cycle (T1), wit…
-
Total inductance of primary/secondary coils includes mutual inductance with aiding fields
1×
Total inductance (La) of the Primary Coil (26) and Secondary Coil (52) is calculated with their fields aiding via Coupling Inductance (Rp), using individual coil inductances (L1, L2) and mutual inductance (M) exp…
-
Switching Secondary Coil-Array maximizes power transfer while keeping pulse-train voltage constant
1×
…g the member of Secondary Coil-Array (505a–505n) maximizes electrical power transfer from Primary Coil (26) to Secondary Coil (52) by keeping the Voltage Amplitude of the Pulse-train (49a–49n, T3, 49a–49n) consta…
-
VIC has a Primary Coil (26) and Secondary Coil (52) topology
1×
The VIC circuit topology includes a Primary Coil (26) and a Secondary Coil (52), between which electrical power is transferred and maximized via the coil switching mechanism.…
-
Primary and secondary coils are bifilar wound in equal length for matched displacement
1×
Both primary coil (957) and secondary coil (958) forming the voltage intensifier circuit (990) are bifilar wrapped in equal length, causing both water molecules to be displaced at the same velocity since their ma…
-
Mutual inductance coupling between bifilar coils forms simultaneous +/- voltage fields
1×
…gnetic inductance coupling between the two bifilar wrapped coils (957/56-958/62) when the primary coil is energized by the incoming voltage pulse train (T4a...T4n).…
-
Primary coil uses .030 Ga. film coated magnet wire, wound longitudinally over the choke coils
1×
Primary Coil (26), typically .030 Ga. film coated magnet wire, is longitudinally wrapped in space relationship on top of and layered bidirectionally (507a...507n) across the spiral-wrap choke coils (501a...501n)…
-
Secondary pickup coil cavity is layered atop the primary coil cavity
1×
Secondary bobbin cavity (506) is placed on top of and in spatial relationship to primary coil cavity (504).…
-
Primary and secondary coils are electrically isolated in the VIC transformer
1×
The primary coil is electrically isolated from the secondary coil (no electrical connection between them) to form the Voltage Intensifier Circuit (AA), as shown in Figure 1-1.…
-
Voltage levels control applied voltage across Resonant Cavity Assembly via amplitude control circuit and primary coil
1×
…3-22) through voltage amplitude control circuit (50), which is electrically linked to the primary coil (26) of the Voltage Intensifier Circuit (60).…
-
Voltage amplitude control circuit (50) simultaneously regulates battery voltage and Fuel Cell gas pressure
1×
…functions at once: it regulates car battery electrical voltage potential (32) applied to primary coil (26), and it regulates gas pressure of the Fuel Cell (120).…
-
Variable voltage range of 1 to 12 volts is applied across the VIC primary coil
1×
…1) up to twelve (12) volts, representing the regulated battery voltage, is applied across primary coil (26) of the Voltage Intensifier Circuit (60).…
-
Cell driver circuit (90) switches ground to primary coil (26)
1×
…function, turning electric ground 'off' and 'on' as applied to the opposite side (48) of primary coil (26), shown in Figure 3-19.…
-
Primary coil pulse waveform duplicates the incoming gated pulse train
1×
The resultant pulse waveform (49a...49n) superimposed onto primary coil (26) in Figure 3-18 is an exact duplicate of the proportional pulse train (47a...47n) driving the cell driver circuit.…
-
Pulse train (47) and primary coil pulse (49) are electrically isolated
1×
Although the primary coil pulse waveform (49) exactly duplicates pulse train (47), the two pulse trains are electrically isolated from each other despite the correspondence.…
-
VIC formed by primary/secondary coils, diode, chokes, and resonant cavity
1×
Primary coil (26), pulsing core (53), secondary coil (52), switching diode (55), resonant charging choke (56), resonant cavity assembly (170), natural water (68), and variable resonant charging choke (62) togethe…
-
Pulsing transformer steps up voltage via primary/secondary coil action
1×
The pulsing transformer (primary coil 26 / secondary coil 52) steps up voltage amplitude during pulsing operations; primary and secondary coils have no direct electrical connection (electrically isolated) to form…
-
Pulsing transformer steps up voltage during pulsing operations
1×
…r (m) steps up voltage amplitude or voltage potential during pulsing operations, with the primary coil electrically isolated from the secondary coil to form the Voltage Intensifier Circuit (AA).…
-
VIC transformer: copper primary coil, resistive secondary coil, transformer-paper wrap, air-gap coupling
1×
In the Voltage Intensifier Circuit transformer, the primary coil is copper wire and the secondary coil is resistive wire, both insulated to prevent shorting; the two coils are joined on the ground side, wrapped o…
-
Duty pulse across primary coil (54) induces field coupled to pickup coil (56)
1×
As duty pulse (53) forms across primary coil (54), electromagnetic field (55) is produced and couples with pickup coil (56), forming voltage potential (57) across the pickup coil.…
-
Resonance achieved at 26V pulse, 10 kHz in Example I
1×
Resonance in the circuit was achieved at a 26 volt applied pulse to the primary coil of the toroid at 10 kHz, causing water molecules to disassociate into elemental hydrogen and oxygen along with previously disso…
-
Step-up toroidal coil specifications
1×
…ial (e.g. 'Ferramic Q6 Permag' powder), 1.50 inch in diameter and 0.25 inch thick, with a primary coil of 200 turns of 24 gauge copper wire and a secondary winding of 600 turns of 36 gauge wire.…
-
Primary coil driven at 50% duty cycle pulse with >5x voltage step-up
1×
The primary coil of the toroid is subjected to a 50% duty cycle pulse; the toroidal pulsing coil provides a voltage step-up from the pulse generator in excess of five times, with actual step-up ratio determined b…
-
Resonance achieved at 26V pulse, 10 kHz on toroid primary
1×
Resonance in the circuit of FIG. 2 was achieved at a 26 volt applied pulse to the primary coil of the toroid at 10 KHz, causing the water molecules to disassociate into hydrogen and oxygen along with previously d…
-
Primary coil driven by 50% duty cycle pulse; inductor is 100 turns of 24 gauge wire
1×
The primary coil of the toroid is subjected to a 50% duty cycle pulse; the first inductor following the toroid is formed from 100 turns of 24 gauge wire, 1 inch in diameter, and when the pulse ends its collapsing…
-
FIG. 9 circuit uses external electromagnetic pulse field via primary coil and switching diode
1×
…rging choke coils by allowing an external electromagnetic pulsing field (F), derived from primary coil A being energized, to traverse coil windings D and E via incoming pulse train Ha...Hn through switching diode…
-
Pulse generation uses two frequency generators: resonant and gated
1×
…cy generator; the gate pulse controls the number of resonant-frequency pulses sent to the primary coil during a period set by the gate frequency.…
-
Pickup coil on transformer core senses resonance for PLL control
1×
…and is interconnected to a scanning circuit and phase lock loop (PLL) circuit to keep the primary coil pulsing frequency locked to the sensed resonant frequency.…
-
Secondary/choke turns ratio determines output voltage (e.g. 30:1 gives 360V from 12V)
1×
…cording to coil turns and size as in a standard transformer; for example, 12 volts to the primary coil with a 30:1 secondary/resonant-charging-choke turns ratio yields 360 volts sent as uni-polar pulses to the ca…
-
Example gate/resonant pulse relationship: 5KHz resonant pulse with 0.5Hz gate at 50% duty
1×
…ng how the gate pulse frequency generator (Figure 6) controls discrete pulses sent to the primary coil.…
-
Example voltage staging: 0-12V primary input, secondary settable to max e.g. 2000V
1×
Figure 4's control means directs 0-12 volts across the primary coil of the pulsing core, and depending on core design parameters, the secondary coil can be set up for a predetermined maximum voltage such as 2000…
-
Primary toroid coil driven at 50% duty cycle producing double pulse frequency via inductor field collapse
1×
The primary coil of the toroid is subjected to a 50% duty cycle pulse and provides a voltage step-up in excess of five times; the stepped-up pulse enters a first inductor (100 turns of 24 gauge wire, 1 inch diame…
-
WFC resonance achieved at 26V pulse, 10kHz on toroid primary
1×
Resonance in the circuit of Figure 2 was achieved with a 26 volt applied pulse to the primary coil of the toroid at 10KHz, causing water molecules to disassociate into elemental hydrogen and oxygen.…