AFFIDAVIT OF ROBERT L. QUEEN
Robert L. Queen, being duly sworn deposes and says, that he is a staff engineer with Materials Joining Consultants, doing business at 981 East Hudson Street, Columbus, Ohio,
1. material samples of 0.50 and 0.75 inch outside diameter tubing as per attachment B and identified therein as stainless steel T-304 was supplied by Stanley A. Meyer;
2. it was requested that Materials Joining Consultants conduct a chemical analysis of the material and to provide other supporting information;
3. the chemical analysis was conducted and the result as stated in attachment A are true and accurate;
4. an analysis of several water samples for sodium and potassium as conducted by R & D Laboratory also was provided for review;
' 5. thereafter an analysis was conducted as to affects of the aforesaid water on the austenitic type 304 stainless steel; and that
6. the results of the analysis as given on the second page
of attachment A is true and accurate.
FURTHER AFFIANT SAETH NOT.
County of Franklin )
State of Ohio )
The above-named Robert L. Queen personally known to me, did appear before me and make Oath that the statement of facts
as recited in his Affidavit are true.
Cmcwel Sooeets
CAROL P:NERIS
RYE, +30 APNE SF eng
: WY COMMISSIU ATtacs Mu¥ 30, 19R4

Page 49
| AVERAGE PHYSICAL PROPERTIES OF PLEXIGLAS SHEET
+ . ‘METHOD™ ONITS. PlezigiasG Plexiglas Plexiglas. « ee > and I UVA Ke. 6 5B
dad
pas volts /mil 500
wis hao ars >
bs No Tracking No Tracking No Tracking
Refer. Data: Dayton Plastic ™ Plastic Engineering Handbook" Jan, 1979 ue coryt

Page 50
AFFIDAVIT OF RELATING TO TECHNICAL CHARACTERISTICS
OF NON-CHEMICAL HYDROGEN GAS GENERATION SYSTEM
Robert L. Ward , being duly sworn deposes anf says that he
has been a chemist for over 27 years, and that he has the education background and technical experience to make him knowledgeable as to the characteristics of hydrogen gas generation testing under given conditions; and that said <= “ar
education comprises:
B.S. Degree in Chemistry 1955
Morehead State University
Morehead Ky, and said background and technical experience comprises:
EMPLOYED BY: Allied Chemical Corp. for 23 Years as _. analytical and R&D chemist:
8 years at South Point, Ohio ;
Chief Chemist & Lab Supervisor 15 years, Ironton, Ohio EMPLOYED BY: Ironton Coke Corp. for 4 years as
Corp. Technical Director Ironton, Ohio
Affiant further states, that
A) Performed the test and sampling of gases derived from Natural water having a potassium and sodium content no greater than that specified in the attached Exhibit A; and that,
B) The above said gas samples were derived and/or generated from the following types of natural water
sources via the non-chemical hydrogen generation
system ; and that
!) Distilled Water
2) Rain Water 5
3) Lake/ Reservoir Water
4) City Tap Water
5) River Water
6) Well Water (as; softened) 7) Ocean Water

Page 51
| C) That only non-oxidizing materials (Stainless steel I #304 ) were immersed in tne above said non-chemical hydrogen generation system during the above said gas test sampling; and that, | D) The above said non-chemical hydrogen generation system housing consists of non-oxidizing material- Clear Acrylic material;
AFFIANT FURTHER SAETH NOT.
Witnesses : , 4 19 SZ,
State of Ohio
County of
Having -appeared before me and known to'me has made Oath «
' that the technical facts stated above are based upon technical ' expertise and opinion and true or believed to be true,
| Notary
' MARIE H. MEYER
NOTARY PUBLIC. STATE OF OHIO
Seal My COMMISSION EXPIRES AUG. 2 1983

Page 52
WATER COLLECTION/TEST OBSERVATION AFFIDAVIT
STANLEY GRAUMLICH AND CHARLES C. HOLBROOK
| Stanley Graumlich, residing at 3672 State Route 62 N.E. ' Washington Court House, Ohio 43210, and
Charlie C. Holbrook, residing at 4907 State Route 41 N.W. Washington Court House, Ohio 43160.
being duly sworn depose and say: that
1. they are personally known to Stanley A. Meyer and have
assisted him in conducting tests on said hydrogen generator system (U.S. patent serial number 6/302,807 filed on 9/16/1981) | for patent recordation and processing since July 198l;and that,
‘2, they are familiar with the contents and disclosure in U.S. | patent anplication Serial Number 6/302,807 filed 9/16/81 by
|, Stanley A, Meyer on said Hydrogen Generator System; and that,
| 3. through association of Affiants with Stanley A. Meyer and
| their continued assistance in conducting tests on said Hydrogen
’ Hydrogen Generator System, that the non-oxidizing similar materia-
Generator System, Affiants are with knowledge that any type of
natural water (as per Exhibit A) is totally operable in said
"plates" (as per Exhibit B) are made of stainless steel tubing or
‘other configuration of stainless steel material (Exhibit E), and | the D.C. electrical potential (constant or pulsed, Exhibit E) | applied to said non-oxidizing "plates" (Exhibit B) is a voltage
with only a minimun current to sustain a potential, and that | 4. for patent recordation and processing, they were requested
| by Stanley A. Meyer to obtain containers of natural water (as per
, Exhibit A) from different natural water sources and to personally
FILE coPY , =
ONLY ON MICROFILM
DONT REMOVE :

Page 53
‘ deliver said water containers with said natural water (Exhibit A) to R & D Laboratory for analysis; and that
S. they were also requested by Stanley A. Meyer to personally deliver said non-oxidizing “plate” material (Exhibit B) to Col-X Corporation for analysis ; and that, by they were also requested by Stanley A. Meyer to personally purchase (Exhibit J) said non-oxidizing housing (Exhibit E) Mat'l (clear acrylic plastic material, as per Exhibit C) for gas-sampli (Exhibit F); and that, 7, affiants ( Charles C. Holbrook/ Stanley Graumlich) obtained said natural water (Exhibit A) ie., distilled water, rain water, river water, city tap water, well water, lake/reservoir water, an ocean water (as per Exhibit A) and seperately placed each type of natural water in containers of non-oxidizing material (sealed 5 gallons plastic buckets) marked as to its contents; and that 8. the marked containers of natural water (Exhibit A) were deliver by Affiants to the R & D Laboratory for analysis as to content, as per attached report - Exhibit A; and that, 9, portion of the natural water (Exhibit A) were taken from each of the sealed containers and placed in specially marked bottles by the director of the R & D Laboratary, the bottles were marked i as to the types and source of the water as per Exhibit A; and that, 10.the natural water remaining in the 5 gallon containers were taken immediately and directly to the home testing laboratory of Stanley A. Meyer for generation of gasses from each of said types of natural water (Exhibit F) by Affiants in the present of said Stanley A. Meyer and said Robert L. Ward; and that,
ON MICROM FESO”
EMove anwt P

Page 54
‘11, each S gallon container of said natural water (Exhibit A)
' was seperatedly poured into said Hydrogen Generator System
' (Exhibit E) having a housing of non-oxidizing material (Exhibit C. "and which housing had an array of non-oxidizing stainless steel '"plates" (Exhibit B) position therein (Exhibit E), the housing ‘was sealed and a direct voltage/low current (constant or pulsed, Exhibit E) potential applied to said non-oxidizing "plates"
_ (Exhibit B); and that,
42. Affiants witnessed the gas test-sampling (generation of
| Bysrbgen gas, Exhibit G) conducted by Stanley A. Meyer and ‘Robert L. Ward, R & D chemist (Exhibit F) with the use of each “ene of natural water (Exhibit A) in said Hydrogen Generator
1 system (Exhibit E); and as observed by Affiants the test |Tesults conforms to the data submitted herein in the Affidavit
iof said Robert L. Ward (Exhibit F and Exhibit G); and that,
13. Affiants further witnessed the collection of said gas-samples
(Exhibit G) from each type of natural water (Exhibit A) in said
Hydrogen Generator system (Exhibit E); the gases collected (Exhibit G) were placed in seperate containers (specially
: prepared via Analytical Research Associates Inc., Exhibit G) appropriatedly marked as to the source of natural water
(Exhibit A) by said Robert L. Ward (Exhibit F); and that,
14, Affiants further witnessed the delivery of said samples of gases (7 individually sealed containers, Exhibit G) directly to Analytical Research Associates, Inc. by said Robert L. Ward and said Stanley A. Meyer for analysis as to gas content of
each of said samples - Exhibit G); and that,
15. Affiants witnessed the initial tests conducted on said | collected gas samples (Exhibit G) by the personnel of the | Analytical Research Associates, Inc.; and that,
rE cont
ONLY ov
N MICROFILM

Page 55
> AFFIANTS further state: that 16, Affiants. witnessed the Hydrogen Gas Control-rate evaluationtesting by Stanley A. Neyer and Stephen F. Meyer, R & D Electron: Design Engineer (Exhibit H), with the use of the various types of ‘ natural water (Exhibit A) in the Hydrogen Generator (Exhibit E- | HG 1004/HG 1005S, HG 1006); and as observed by AFFIANTS the test results conforms to the test-data submitted herein in the Affidav: of said Stephen F. Meyer (Exhibit E); and that,
TURTHER AFFIANTS SAETH NOT.
LAL 2 Cpanel py e142
CHARLES C, HOLBROOK DATE
2Y GRAUMLICH DATE
STA
WITNESSED BY:
STANLEY Ser E——IDATE
The above-name Stanley A. Meyer, Charles C. Holbrook, and Stanley Graumlich, personally known to me, did appear before me and make Oath that the statement of facts as recited in the above AFFIDAVIT are truce.
MARIE H. MEYER
ROTARY PUBLIC STATE OF Oni0
MY COMMISSION EXPIRES AUG 2 1983
wil bul PDs waAranyv

Page 56
Drawing sheet — no readable text.

Page 57
Drawing sheet — no readable text.

Page 58
CONSTANT AND SUBSTAINED HYDROGEN GAS-FALME AT
THE RATE OF HYDROGEN GAS- PRODUCTION DURING
LOW VOLTAGE STIMULATION: 0.5 INCH HIGH FLAME
CONSTANT AND SUBSTAINED HYDROGEN GAS-FLAME AT THE
RATE OF HYDROGEN GAS PRODUCTION DURING VOLTAGE -
STIMULATION: MELTING STAINLESS STEEL 12 Ga WIRE
MATERIAL : FLAME TEMPERATURE 2500 DEGREES F PLUS

Provenance
- Pages
- pages 48–58 of 140
- Binder
- WFC Project Binder 423-DA
- Method
- pdftoppm 300dpi + tesseract 5 (eng), orientation-corrected
- Source
- WFC International Independent Test-Evaluation Report (1995), scanned binder
- Attribution
- Robert L. Queen; Stanley Graumlich; Charles C. Holbrook; Robert L. Ward