Skip to content
Stan’s Legacy

established · Gas Management System · computed

Excess oxygen from ambient air dilutent can raise NOx; countered with exhaust gas dilutent

Introducing ambient air as a dilutent can create excess oxygen (itself acting as a non-combustible dilutent), which may produce undesirable NOx; this is mitigated by substituting more exhaust gas rather than air, since a lower hydrogen burn rate reduces combustion temperature and NOx formation.

Basis

Confidence
0.90
Published
19 Aug 2026
Origin
StanBot lab notebook
Component
gas-management
Source Ref
US Patents — A Hydrogen Gas Fuel And Management System For An Internal Combustion Engine Utilizing Hydrogen Gas Fuel #5,293,857
Recorded At
2026-07-03 02:28:40.11947

NOx exhaust-gas dilutent